Titan - Pressure Drop Calculations

Titan Flow Control, Inc. also offers downloadable Pressure Drop Charts for your convenience. Click on the images to the right to download the Adobe PDF sheets for Titan FCI's Strainer and Check Valve models. For additional help determining the pressure drop for a …

Đọc thêm

free of pressure drop calculation for conical strainer for ...

The expected pressure drop across the strainer should not cause the downstream operating pressure to fall below the minimum required pressure of the line e.g. NPSH for a pump. The perforations of the strainer should be slightly smaller than the smallest piece of debris that is expected to flow through it.

Đọc thêm

Engineering Data Screen Openings for Strainers

How to Use: 1) Determine the pressure drop (P1) through the strainer with water flow and standard screens. 2) If non-standard screens (i.e. 40 mesh, etc.) are being used, apply factors in Chart #1 to determine corrected pressure drop (P2). 3) Multiply P1 or P2 (if used) by the specific gravity of the fluid actually flowing through the strainer to get P3. 4) Using Chart #2 multiply P3 by the ...

Đọc thêm

Cyclone Design Equations Formulas Calculator - Pressure Drop

P drop = pressure drop: Q = gas flow rate: P = absolute pressure: p gas = gas density: u = air viscosity: u gas = gas viscosity: K = proportionality factor: T = temperature: v = settling velocity: S = separation factor: N = approximate effective turns: h = inlet height: L cylinder = cylinder length: L cone = cone length: d cut = cut diameter: W ...

Đọc thêm

Pressure Drop - LMNO Engineering. Fluid flow calculations ...

Pressure Drop Drawing and Equation: Pressure Drop Equation Derivation. For steady flow of an incompressible fluid in a constant diameter horizontal pipe using the Darcy-Weisbach friction loss equation, the energy equation from location 1 to 2 is expressed in terms of pressure drop as:

Đọc thêm

Y-Strainer Flow Rate Vs Pressure Drop | Sure Flow ...

Y-Strainer Flow Rate Vs Pressure Drop. "Y" Strainers take their name from their configuration. They are most commonly used in pressurized lines, gas or liquid, but can also be used in suction or vacuum conditions. They are intended for applications where small amounts of solid particulate are expected, and where clean-out will be infrequent.

Đọc thêm

How to Overcome Air Filter Pressure Drop Measurement ...

The filter is removed, and a second pressure measurement is taken. The new pressure with the filter removed is .52" w.c. This therefore results in a calculated filter pressure drop of .12" w.c. (.52 – .40 = .12). Why It's Incorrect. This test may sound good on the surface, but the result will be an inaccurate filter pressure drop.

Đọc thêm

Guidelines for The Preparation of Strainer Specification ...

8.4. For temporary cone type strainers break off flanges (spool piece) to be considered for ease in removal. 8.5. Temporary conical strainers are to be placed with the cone pointing opposite to the direction of flow. 9. Pressure Drop across a Strainer / Mesh Number

Đọc thêm

Special Process Items | Flame Arrester, Spray Nozzle ...

24.9.4 Pressure Drop Calculation – As a general thumb rule, an engineer should allow for two extra hard tees for a 'clean' strainer when performing preliminary pressure drop calculations. A more accurate pressure drop estimate should then be obtained through the specific strainer vendor.

Đọc thêm

Handling the pressure drop in strainers | SpringerLink

A model of pressure drop calculation for strainers based on the screen opening, viscosity of the fluid, Component Factor, Body Factor, etc. has been developed in this paper through a case study of the pressure drop calculation for a 12″ class 300 strainer in 22Cr duplex material.

Đọc thêm

Pressure Drop Across Coarse Strainers - Industrial ...

Pressure Drop Across Coarse Strainers - posted in Industrial Professionals: Hello everyone,I'm working on a project where it has been proposed to install a coarse strainer on the suction side of a pump, to prevent large objects damaging the pump. The strainer is a flat plate, with as much 10mm holes as possible punched into it. I'd like to calculate the pressure drop across it, and am ...

Đọc thêm

Strainer Selection Chart Screen Equivalents Magnets ...

• Low Pressure Drop • Streamlined Design • Large Strainer Screen ... Fabricated "Y", Basket, and Tee Type Strainers; Temporary Cone, Basket and Plate Strainers. STEAM Working Pressure Non Shock Maximum WATER, OIL, or GAS Working Pressure Non Shock Maximum.

Đọc thêm

Wye Strainer Pressure Drop Charts and Specs

Pressure drop happens due to a resistance in the flow of fluid at junctions (like wye strainers). The specific pressure drop of wye strainers depends on the brand and type that is used. In the graphs and charts below you can see the changes in pressure drop of four of our most commonly used brands of wye strainers: • Titan Flow Control.

Đọc thêm

Flow in pipes - Calculators for pressure drop, pipe ...

Calculate pressure drop for known flow rate or calculate flow rate for known pressure drop. Friction factor calculation included. ... For compressible flow calculation gas state equation can be used. For ideal gases, velocity for Mach number M < 1 is calculated using following equation: ...

Đọc thêm

PRESSURE DROP CHARTS - WYE & BASKET STRAINERS

STRPDC-0121 TECHNICAL AND PERFORMANCE DATA PRESSURE DROP CHARTS f WYE & BASKET STRAINERS TITAN TITAN FLOW CONTROL, INC. Tel: 910-735-0000 s Fax: 910-738-3848 s [email protected] 290 Corporate Drive s PO Box 7408 s Lumberton, NC 28358 TITAN FLOW CONTROL, INC.

Đọc thêm

6 Factors for Sizing & Selecting a Filter or Strainer

As the filter bag or strainer begins to fill, the pressure drop increases as the filtered debris reduces the filter's surface area. Once a point is reached where the pressure to overcome this is too great, the desired flow through the filter will be compromised. The amount of filter surface area and the loading of particulate being filtered ...

Đọc thêm

Equivalent Length of Fittings and Valves

This application is a calculator for calculating 'Equivalent Length of Fittings and Valves'. For calculating Pressure Drop across a pipe route, we need to calculate the total length or rather total equivalent length of that pipe route including all valves, fittings, etc.

Đọc thêm

Calculator: Pressure Loss through Piping for Gas | TLV - A ...

Online calculator to quickly determine Pressure Loss through Piping for Gas. Includes 53 different calculations. Equations displayed for easy reference.

Đọc thêm

Natural Gas Line Sizing using General Pressure Drop Equation

Then we got : Gas velocity = 33.18 ft/s. End pressure = 43.27 psia, or pressure drop = 0.43 psi (use equation 1) By using process simulator we got: Gas velocity = 34.18 ft/s. End pressure = 43.28 psia, or pressure drop = 0.426 psi. The result is similar too.

Đọc thêm

Pressure Drop Formula: Definition, Concepts and Examples

Pressure drop is quantity of line pressure, which is lost forever when gas flows through a device in gas line. This loss of pressure is caused by the frictional resistance of the parts exposed to the gas. Each instrument and fitting cause some certain amount of drop in pressure. Learn the pressure drop formula.

Đọc thêm

Pressure Drop Online-Calculator

Pressure Drop Online-Calculator Calculation of pressure drops of flowing liquids and gases in pipes and pipe elements (laminar and turbulent flow). Note: Calculations are possible only, if Javascript is activated in your browser. Pressure Drop Online-Calculator for small mobiles. This version is usable for browsers without Javascript also.

Đọc thêm

STR990-1 Pressure Drop Data Y - Colton Industries

Strainer Size: 1-1/4" a) Using FIGURE 1 the pressure drop is determined to be 1.0 psid using the standard screen Filtration: 100 mesh lined 1/32" perf. b) Looking at the replacement screen data sheet, we find that the % open area of 100 mesh is 30%

Đọc thêm

Pressure Drop Basics & Valve Sizing - Watts

Pressure Drop Table Available Pressure at Valve Model # Min Flow Min Flow to 5 1020304560 100 * Rate ASSE 1017 Flow Rate in GPM 431 0.5 4 7.5 11 16 20 25 29 38.5 432 0.5 7 15 20 30 36 45 52 67 433 0.5 10 243451648093 123 434 0.5 15 40 55 82 101 125 146 190 1432 0.5 1.5 14 18 27 33 40 46 60

Đọc thêm

(PDF) calculation sheet for pressure drop | Janani Janu ...

calculation sheet for pressure drop. CALCULATION SHEET DOC. No. : KT-110209 설계 계산서 DATE : 2011. 2. 9 OPENING AREA & PRESSURE DROP CALCULATION OPERATING CONDITION ITEM NO. 25 SFT 004 25 SFT 006 25 SFT 001 25 SFT 003 NOMINAL PIPE SIZE DN400 DN500 DN400 DN500 FLUID NAME HC gas HC gas HC gas + Water HC gas Pressure …

Đọc thêm

Temporary Strainers | Cone Strainers | Weamco

Temporary Strainers Weamco (The First Name in Strainers) has been manufacturing dependable high quality Permanent and Temporary Strainers since 1973. Industries such as Pipelines, Hydrocarbon, Chemical, Power, Gas, Pulp & Paper, Process Plants, and Refineries all over the world have come to depend on Weamco's impeccable service, quality and ...

Đọc thêm

PRESSURE DROP CHART - Keckley

PRESSURE DROP CHART 10 PRESSURE LOSS - [PSI] 200 300 400 500 600 700 800 900 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 20000 30000 40000 50000 FLOW RATE - [GPM] 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" 0. 1 0. 2 0 3 0. 4 0. 5 0. 6 0. 7 0. 8 0. 9 3 9 Fabricated Temporary Cone/Basket Strainers This pressure drop chart is based on the flow ...

Đọc thêm

Strainers | Spirax Sarco

The greater the free area (and the coarser the screen), the higher the flow capacity and ultimately the lower the pressure drop across the strainer. As most strainer screens have very large straining and free areas, the pressure drop across the strainer is very low when used on steam or gas systems (see Example 12.4.1).

Đọc thêm

(PDF) Analysis of Cyclone Pressure Drop

A new method to analysis cyclone pressure drop is reported. The frictional pressure loss is the primary pressure loss in a cyclone. The air stream travel distance is a function of cyclone diameter.

Đọc thêm

Y Strainer Pressure Curve | Y Strainers Pressure Drop

Pressure Drop Curves for Y Strainers. Notes: These charts are based on the flow of clean water at ambient temperature. Consult our Engineering Department for pressure drop information for steam, gases or viscous fluids.

Đọc thêm

Pressure Drop Chart -

Pressure Drop Chart System fluid passing through a Spirovent or Spirotrap will create a certain pressure drop, depending on the size of the nozzles, diameter of the shell, and the volume (flow) and speed (velocity) of the fluid. Figures D-1 and D-2 (pages 3 and 4) show the pressure drops and water velocities for all product sizes up to

Đọc thêm

Pressure Drop Curves for Temporary Strainers

To approximate the pressure drop for mesh lined temporary cone and basket strainers, apply the following multipliers to the chart data. As an example, the estimated clean differential pressure for a flow rate of 60 GPM with a 2" size temporary cone or basket strainer is 2 PSI; if it were a 60 mesh lined configuration, it would be 2 PSI x 1.4 ...

Đọc thêm

Temporary Strainer

As an example, the downstream pressure should never fall below the NPSHr of a pump. Perforation size or screen size. The strainer should be slightly smaller than the smallest piece of debris that is expected to flow through it. If the perforations are too small, a high pressure drop could develop across the strainer and cause it to fail.

Đọc thêm

Natural Gas Pipeline - Flow Rate - Pipeline Engineering

Modified Colebrook equation based on US Bureau of Mines experiments; gives higher pressure drop compared to original Colebrook equation. Gas Flow Rate - Weymouth Does not consider pipe roughness; uses an efficiency factor used for high-pressure gas gathering systems; most conservative equation that gives highest pressure drop for given flow rate.

Đọc thêm

Temporary Pipeline Strainers and Screens

Basket style temporary strainers are oriented facing down stream (with the flow) and the particles begin to collect in the flat section. Basket style strainers have less volume and surface area than the cone style temporary strainer and therefore a slightly higher pressure drop; their open area ratio is …

Đọc thêm

Temporary Cone, Basket, and Flat type Strainers

Size 20.0"/25.0" truncated basket strainers with mesh lined outside. Double screen stainless steel 316 truncated strainers. Heavy duty 316 stainless steel temporary cone basket type straine with double mesh outside for reverse flow. With support rings on outter basket to prevent mesh tears/rips under high pressure with support rings inside.

Đọc thêm

Pressure Drop Online Calculator PDA

Pressure Drop Online Calculator ... Strainers and grids / Conical strainer. Diameter of pipe D:: Flow medium: Flow medium: Condition: liquid gaseous: Volume flow: Weight density: Dynamic viscosity: Additional data for gases: Pressure (inlet, abs): Temperature (inlet): ...

Đọc thêm